Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8549764
| No.8549764
- Product Categories
- Friendly Links
| Information Name: | Cold shrink cable accessories supply 110KV |
| Published: | 2011-09-09 |
| Validity: | 30000 |
| Specifications: | |
| Quantity: | 1.00 |
| Price Description: | |
| Detailed Product Description: | This product is suitable for the 64/110KV voltage XLPE insulated power cables. Advantages: (1) all-liquid silicone rubber - High-elastic (-60 ℃ -200 ℃): the same breath with the cable, the cable maintain a permanent body of the radial pressure, effective sealing, the absolute moisture, water. - High resistance to tear: prevent cracking caused by improper construction and scratches. - Anti-aging: Anti-corona, anti-leakage; material itself good electrical properties, to ensure the safety of operation. (2) sub-structure - Small size, light weight, so that construction positioning more accurate. - Increase the potential to climb away, safer and more insurance. (3), cold shrink - Saving time, effort, more convenient and faster. - With interference fit condition to ensure that the interface pressure, can effectively uniform electric field, longer life. (4) easy maintenance - Dry-type terminal, no leakage. - Surface water-repellent, not dust, have a good self-cleaning, effective anti-climb lightning network. (5) Flexible attachments - Free to clamp. - Environmental requirements for running low, anti-vibration, no decrepitation. (6) to a wide range A partial discharge test at room temperature is not greater than 96kV power devolution devolution of power less than 1C 5pC 96kV qualified 2 thermal cycle voltage test - by 20 thermal cycles required to complete the following test evaluation voltage test 3 high-temperature partial discharge test 96kV power delegated delegated power is not greater than 5pC 96kV qualified than 1C 4 Partial discharge test at room temperature is not greater than 96kV power delegated delegated power is less than 1C 5pC 96kV qualified 5 impulse voltage test 550kV, negative polarity of the 10-times no breakdown, no flashover 550kV, negative polarity of a 10 composite sample is not qualified breakdown and flashover 6 Lightning impulse voltage test frequency voltage test 160kV, 15min, no flashover, no breakdown 160kV, 15min, no flashover, no breakdown of qualified 7 rain pressure test 185kV, 1min, no flashover, no breakdown 185kV, 1min no flashover, no breakdown of qualified 8 6h-frequency voltage test - 192kV, no flashover, no breakdown - 9 1min power frequency voltage test - 230kV, no flashover, no breakdown - 10 radio interference test 81kV, 1MHz, the radio interference voltage is less than 450μV 81kV, 1MHz, the radio interference voltage is less than 47μV qualified |
Admin>>>
You are the 8135 visitor
Copyright © GuangDong ICP No. 10089450, Wald heat-shrinkable Material Co., Ltd., Wuhan, Zhengzhou Branch All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 8135 visitor
Copyright © GuangDong ICP No. 10089450, Wald heat-shrinkable Material Co., Ltd., Wuhan, Zhengzhou Branch All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility

